Australia
K-Clad Wall Panel
| Surespec | : |
0435-Cladding – Planks and Weatherboards
0471-Thermal insulation and pliable membranes
0437-Cladding - Insulated Panel Systems
|
| Speedspec | : |
07200-Thermal & Acoustic Insulation
07462-Cladding External Walls
|
| Application | : | Variety of non-Section J buildings such as largescale logistics facilities | Agricultural facilities |
| Installation | : | Horizontal | Vertical |
| Trapezoidal Profile | : | Yes |
| Type | : | Panels | PIR Boards |
| Core Thickness | : | 30 mm |
| Lengths | : | Standard lengths: 2.0m - 12.0m | Export of Australia / Sea freight to WA: 11.8m |
| Overall Thickness | : | 65 mm |
| Panel End Cut Back End Lap Horizontally Laid | : | 75 mm |
| Panel End Cut Back End Lap Vertically Laid | : | 75 mm |
| Panel End Cut Back Maximum Cut Back | : | 200 mm |
| Panel End Cut Back Minimum Cut Back | : | 50 mm |
| Weight | : | 8.00 kg/m² |
| Width | : | 1000 mm |
| Insulated Core | : | Polyisocyanurate (PIR) core |
| Product R-Value at 23°C | : | 1.30 m²K/W |
| Product Tolerances | : | Length < 3 m: ± 5 mm | Length > 3m: ± 10 mm | Cover Width: ± 2 mm | Thickness: ± 2 mm | Squareness: ≤ 0.6% of width |
| Product U-Value at 23°C | : | 0.7 W/m²K |
| Seals | : | All panel joints have a factory applied weather seal fitted on the underside of the side lap to automatically seal the joint between panels |
| Through-Fix Fixing Detail | : | Yes |
| Total R-Value Heat Flow In (Summer) | : | 1.41 m²K/W |
| Total R-Value Heat Flow Out (Winter) | : | 1.52 m²K/W |
| Testing | : | AS/NZS: 1530.3: 1999 | AS 5637.1: 2015 / ISO 9705 2003 |