Surespec | : |
0435-Cladding – Planks and Weatherboards
0471-Thermal insulation and pliable membranes
0437-Cladding - Insulated Panel Systems
|
Speedspec | : |
07200-Thermal & Acoustic Insulation
07462-Cladding External Walls
|
Colour | : | Grey | Gold | Silver |
Installation | : | Horizontal | Vertical |
Material | : | Steel |
Profile | : | Mini-micro | Micro-rib | Plank | Wave |
Trapezoidal Profile | : | No |
Type | : | Panels | PIR Boards |
Cover Width | : | Non standard cover: 900 mm | Standard cover: 1000 mm |
Length | : | 13700 mm |
Lengths | : | Standard Lengths: 2.0 mm - 13.7 mm | Longer Lengths (Non-Standard): 13.7 mm - 16.1 mm | Export of Australia/ Seafreight to WA: 11.8 mm |
Nominal Thickness | : | 50 mm | 80 mm | 100 mm | 140 mm |
Packaging | : | 1200 mm |
Weight | : | 10.5 kg | 11.8 kg | 12.0 kg | 13.7 kg, 13.7 kg |
Width | : | 1000 mm |
Acoustic Performance | : | Sound reduction index (SRI) of Rw = 24 - 26dB* |
Fire Performance | : | Ignitability Index: 0 | Spread of Flame Index: 0 | Heat Evolved Index: 0 | Smoke Developed Index: 2 |
Flatness | : | L = 200 mm: 0.6 mm | L = 400 mm: 1.0 mm | L > 700 mm: 1.5 mm | Bowing: 2 mm per metre length upto maximum 20 mm |
Frequency | : | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz |
Insulation Core | : | Polyisocyanurate (PIR) core |
Product R-Value at 23°C | : | 2.24 m²K/W | 3.68 m²K/W | 4.61 m²K/W | 6.47 m²K/W |
Product tolerance | : | Length < 3 m: ± 5 mm | Length > 3m: ± 10 mm | Cover Width: ± 2 mm | Thickness < 100 mm: ± 2 mm | Thickness > 100 mm: ± 2% | Squareness :≤ 0.6% of width |
Product U-Value at 23°C | : | 0.44 W/m²K | 0.27 W/m²K | 0.21 W/m²K | 0.15 W/m²K |
Rw | : | 24 |
Seals | : | All panel joints have a factory applied weather seal fitted into the panel groove to automatically seal the joint between panels |
Secret-fix fixing detail | : | Yes |
Smoke Growth Rate Index | : | < 100 |
SRI | : | 20 dB | 18 dB | 20 dB | 24 dB | 20 dB | 29 dB | 39 dB | 46 dB |
Total R-Value Heat Flow In (Summer) | : | 2.31 m²K/W | 3.70 m²K/W | 4.59 m²K/W | 6.38 m²K/W |
Total R-Value Heat Flow Out (Winter) | : | 2.50 m²K/W | 4.01 m²K/W | 4.98 m²K/W | 6.92 m²K/W |
CodeMark Certificate of Conformity | : | Certificate number: CM20113 |
FM 4880 Approval Standard | : | Class 1 fire rating of building panels or interior finish materials | Unlimited height for thicknesses 50 mm to 140 mm and panel width of 1000 mm only |
FM 4881 Approval Standard | : | Class 1 exterior wall systems | Unlimited height for thicknesses 50 mm to 140 mm and panel width of 1000 mm only |
NCC Group Test | : | Group 2 | AS 5637.1: 2015 | ISO 9705 2003 |