Australia
KS1000RW Trapezoidal Wall Panel
| Surespec | : |
0522-Partitions - Framed and lined
0471-Thermal insulation and pliable membranes
0437-Cladding - Insulated Panel Systems
|
| Speedspec | : |
07200-Thermal & Acoustic Insulation
07462-Cladding External Walls
|
| Installation | : | Horizontal | Vertical |
| Material | : | Steel |
| Trapezoidal Profile | : | Yes |
| Type | : | Panels | PIR Boards |
| Core Thickness | : | 40 mm | 60 mm | 70 mm | 100 mm | 120 mm | 140 mm |
| Length | : | 13700 mm |
| Length option | : | Standard Lengths: 2.0 m - 13.7 m | Longer Lengths (Non-Standard): 13.7 m - 16.1 m | Export of Australia / Sea freight WA: 11.8 m |
| Overall Thickness | : | 75 mm | 95 mm | 105 mm | 135 mm | 155 mm |
| Panel End Cut Back | : | Minimum Cut Back: 50 mm | End Lap Horizontally Laid: 75 mm | End Lap Vertically Laid: 75 mm | Maximum Cut Back: 200 mm |
| Weight | : | 8.5 kg/m² | 9.1 kg/m² | 9.2 kg/m² | 10.4 kg/m² | 10.9 kg/m² |
| Width | : | 1000 mm |
| Fire Performanc | : | Ignitability Index: 0 | Spread of Flame Index: 0 | Heat Evolved Index: 0 | Smoke Developed Index: 2 |
| Frequency | : | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz |
| Insulation Core | : | Polyisocyanurate (PIR) core |
| Product R-Value at 23°C | : | 1.91 m²K/W | 2.87 m²K/W | 3.36 m²K/W | 4.79 m²K/W | 5.73 m²K/W |
| Product Tolerances | : | Length < 3 m: ± 5 mm | Length > 3m: ± 10 mm | Cover Width: ± 2 mm | Thickness < 100 mm: ± 2 mm | Thickness > 100 mm: ± 2% | Squareness: ≤ 0.6% of width |
| Product U-Value at 23°C | : | 0.52 W/m²K | 0.34 W/m²K | 0.29 W/m²K | 0.20 W/m²K | 0.17 W/m²K |
| Rw | : | 24 |
| Seals | : | All panel joints have a factory applied weather seal fitted on the underside of the sidelap to automatically seal the joint between panels |
| Smoke Growth Rate Index | : | < 100 |
| SRI | : | 20 dB | 18 dB | 20 dB | 24 dB | 20 dB | 29 dB | 39 dB | 46 dB |
| Thermal Conductivity (λ Value) | : | 0.023 W/mK @23°C (insulant thickness = 40mm) | 0.022 W/mK @23°C (insulant thickness ≥ 60mm) |
| Through-Fix Fixing Detail | : | Yes |
| Total R-Value Heat Flow In (Summer) | : | 1.99 m²K/W | 2.92 m²K/W | 3.39 m²K/W | 4.77 m²K/W | 5.67 m²K/W |
| Total R-Value Heat Flow Out (Winter) | : | 2.16 m²K/W | 3.16 m²K/W | 3.68 m²K/W | 5.17 m²K/W | 6.14 m²K/W |
| Certification | : | Greentag Certificate | FPA Gold member | Green Building Council Australia | We Buy Green Power | EPD |
| FM 4880 Approval Standard | : | Class 1 fire rating of building panels or interior finish materials | Unlimited height for thicknesses 40 mm to 120 mm |
| FM 4881 Approval Standard | : | Class 1 exterior wall systems | Unlimited height for thicknesses 40 mm to 120 mm |
| NCC Group Test | : | Group 2 | AS 5637.1: 2015 | ISO 9705 2003 |